Plan a utility or mechanical room
Add the breaker box, water heater, softener, filter, sump basin, boiler, battery, inverter, dehumidifier and EV charger from the Utility & Mechanical section at the end of the Garage or Laundry Room tab, and the generator and AC condenser from the furniture panel's Outdoor tab. Keep the panel's working space clear, hang wall units with Mount (bottom edge), and check it in 3D.
A utility room is where the house's equipment lives: the electrical panel, the water heater, water treatment, the furnace or boiler, a sump pump, and more and more often a home battery, a solar inverter and an EV charger in the garage. The room is usually small and the equipment isn't, so the plan's real job is keeping working space in front of each piece and keeping things that need water, drains and venting together.
RoomSketch3D has a Utility & Mechanical section at the end of the Garage and Laundry Room tabs in Furnish (and in the furniture panel's Outdoor tab for the outdoor units), with twelve generic pieces at typical sizes. The tank water heater and furnaces were already in the app's Equipment section; the new pieces join them.
This guide lays out a basement utility room and a garage equipment wall, gives the clearances people plan for, and says what the app doesn't model (pipes, vents, wiring, gas lines) and how to allow for it.
What you'll need
- •A RoomSketch3D account on the web, iPhone, iPad or Android
- •Your house plan (or the room's inside size) and where the water main, drain and electrical service come in
Step by step
- 1
Find the Utility & Mechanical pieces
In Furnish, pick Garage or Laundry Room and scroll to the end for Utility & Mechanical. The EV Charger (Wall), Standby Generator and AC Condenser (Outdoor Unit) are also in Utility & Mechanical on the panel's Outdoor tab (next to Indoor at the top of the panel), for the outside of the house. Or search breaker, panel, tankless, softener, sump, boiler, battery, inverter, EV charger or generator, in any of the app's nine languages.
Piece Size (W × D × H) How it's placed Breaker Box (Wall Cabinet) 15 × 4 × 36 in On the wall, bottom edge 42 in Tankless Water Heater 18 × 10 × 30 in On the wall, bottom edge 48 in Wall-Hung Boiler 18 × 14 × 34 in On the wall, bottom edge 44 in Whole-House Water Filter 16 × 6 × 24 in On the wall, bottom edge 36 in Home Battery (Wall) 30 × 7 × 46 in On the wall, bottom edge 12 in Solar Inverter 16 × 8 × 30 in On the wall, bottom edge 40 in EV Charger (Wall) 12 × 6 × 16 in On the wall, bottom edge 40 in Water Softener 36 × 18 × 48 in On the floor: resin tank and brine tank side by side Sump Pump Basin 24 × 24 × 36 in In the floor: the basin is flush, 36 in is the top of its discharge pipe Dehumidifier 15 × 11 × 24 in On the floor Standby Generator 48 × 26 × 30 in Outside, on the ground AC Condenser (Outdoor Unit) 30 × 30 × 32 in Outside, on the ground Already in the app: Water Heater (22 in round, 60 in tall) and the vertical and horizontal furnaces.
Furnish → Garage, scrolled to Utility & Mechanical. - 2
Lay out a basement utility room
Draw the room with interior walls (drawing interior walls), or start a Rectangular Floor Plan for the room alone. The worked example is 10′ × 8′: - Panel wall: the Breaker Box on the wall nearest where the service comes in, with nothing in front of it (see the next step). - Plumbing wall: the water main comes in, goes through the Whole-House Water Filter and the Water Softener, then to the Water Heater or Tankless Water Heater. Lining them up in that order on one wall keeps the pipe runs short. The softener needs a drain and an outlet; the tank heater needs about 2 ft clear in front for service. - Furnace or Wall-Hung Boiler: on an outside wall if it vents through the wall, with the clearances in its installation manual. - Sump Pump Basin: in the low corner where it already is (it's in the slab), with the lid uncovered and room to lift the pump out. - Dehumidifier: near the sump or a floor drain, away from the panel. Select any piece to type the real size from its label or spec sheet.
A 10′ × 8′ utility room with furniture names on (View & Layers → Show furniture labels): the breaker box alone on the left wall, water treatment in a line along the top wall. - 3
Keep the working space in front of the panel
Electrical panels need a clear working space in front so someone can stand there and work safely. For a typical home panel (up to 150 volts to ground), OSHA's rule for workplaces is a space 3 ft deep, 30 in wide or the width of the equipment, whichever is greater, and 6½ ft of headroom (6¼ ft for installations before August 13, 2007), and it may not be used for storage. Electrical codes for homes use the same numbers; your inspector has the final say. On the plan, mark that 30 × 36 in rectangle in front of the Breaker Box with the tape measure (use its Area mode) and keep every floor piece out of it. A dehumidifier or shelving unit parked in front of a panel is the most common mistake in real utility rooms.
The breaker box hangs with its bottom edge at 3′6″; change it with Mount (bottom edge). - 4
Wall-mounted equipment: heights and stacking
The breaker box, tankless heater, boiler, filter, battery, inverter and EV charger hang on the wall. Drag one onto the wall; select it and use Mount (bottom edge) to set how high its bottom edge sits. Because they hang, a floor piece can stand under them without Flow check calling it an overlap, which is right for a softener under a filter, but not for anything that would block the panel. Typical placements: a home battery low on the wall (its 12 in default) with the solar inverter beside or above it; check the battery's manual for the clearances it needs to the sides and from doors and windows, which vary by product and local code. A tankless heater on an outside wall if it vents through the wall.
- 5
Garage: the EV charger and the equipment wall
Put the EV Charger (Wall) on the wall nearest the side of the car with the charge port, roughly level with where the car's nose or tail stops, so the cable reaches without crossing the walkway. Add the car you drive from the Garage tab's Vehicles to check: the cable reach is in the charger's spec sheet (often 18 to 25 ft). Many houses put the panel, water heater and softener in the garage too: the same working-space rule applies, and a car door swinging into the panel space counts as blocking it. See the garage layout guide for car sizes and door clearances.
- 6
Outside: the generator and AC condenser
Place the Standby Generator and AC Condenser (Outdoor Unit) on the yard around the house (from the Outdoor tab of the furniture panel, or search). Manufacturers set minimum distances: a condenser typically wants open space on all sides and above for airflow, and a standby generator has minimum distances from the house wall and from windows, doors and vents because of its exhaust. Those numbers are in each unit's installation manual and your local code; measure them on the plan with the tape. Yards aren't under a ceiling, so Flow check doesn't height-check them there.
- 7
See it in 3D
Open the 3D view and tick Dollhouse. Look at the panel wall from the door: is anything in front of the breaker box? Are the wall units at heights you can read and service? In the garage, check that a parked car still leaves room to walk past the charger.
The utility room in 3D.
Tips
Draw it where it really is
Equipment is expensive to move. If you're finishing a basement, place the existing panel, heater and sump first and plan the new rooms around them, not the other way round.
Put outlets and circuits on the electrical plan
The softener, sump pump, dehumidifier, EV charger and tankless heater all need power. Add outlets and circuits as you go: see Electrical plan guide.
Laundry next door
A washer and utility sink share the same water and drain. See Laundry room layout if the two rooms are side by side.
Common mistakes
Shelving in front of the panel
The space in front of a panel isn't storage. Keep the 30 × 36 in working space and headroom clear on the plan and in the room.
Boxing in the sump
A closet or wall built over the sump basin makes the pump impossible to service. Leave its lid in the open.
Assuming the app routes pipes or vents
The app places the equipment, not the pipes, ducts, flues, gas lines or wiring between them. Have a plumber, HVAC contractor or electrician confirm the routes and clearances.
Frequently asked questions
How much space do I need in front of an electrical panel?
For a typical home panel, a working space 3 ft deep and at least 30 in wide (or the panel's width if wider), with 6½ ft of headroom and no storage in it. Your local inspector has the final word.
Where should the water softener go?
Usually after the whole-house filter and before the water heater, near a drain and an outlet. Lining the filter, softener and heater up on one wall keeps the pipes short.
Can I put the EV charger outside?
Yes. The EV Charger (Wall) is on the Garage tab and the furniture panel's Outdoor tab; hang it on an outside wall or a post near the driveway.
Why is the sump basin 36 inches tall?
The basin sits flush with the floor; the 36 in is the top of the discharge pipe rising out of it.
Sources
- OSHA 29 CFR 1910.303(g)(1), working space about electric equipment — Working space width "the width of the equipment or 762 mm (30 in.), whichever is greater"; depth 0.9 m (3 ft) for 0–150 V to ground (Table S-1, condition A); headroom 1.98 m (6.5 ft) for installations on or after August 13, 2007; "may not be used for storage."
Start designing your room
Draw it, furnish it, walk through it in 3D — on web, iOS, and Android.
Open RoomSketch3DOne-time purchase · No subscription · Web, iOS & Android